Patz
Model 1512 Manure Pump |
-
Plunger Size: 7 x 15 in.
-
Stroke Lengths: 20 in., 17 in. and 14 in.
-
Hole Size for Pump Installation: 5 ft. wide x 14
ft. long x 7 ft. 3in. deep (approximately)
-
Floor Space Required for Pump: 3 ft. 2 in. x 11
ft. (approximately)
-
Weight: 2,350 lb. (approximately)
-
Safety Railing: Standard equipment
-
Pipe Length: Recommended maximum length of pipe
with no elbows, 150 ft. Deduct 5 ft. for each 22-1/2°
elbow used and 10 ft. for each 45° elbow. Up
to 90° of elbows may be used in one installation
-
Pipe Size: Choose 15" or 12" PVC pipe
-
Storage Height (Head): Maximum storage height (head)
is 25 ft.
-
This is measured from center line of pipe at manure
pump to top of manure in storage area
|
|
Patz
Model 3333 Multi-Use Vertical Pump |
-
Tapered-bore drive pulley mounts to a 1-1/8-inch
(29 mm) drive shaft with a greaseable flange bearing
at the top of the drive tube
-
Easy access to oil reservoir
-
High-volume delivery
-
Protection against bearing contamination
-
Bearing seals can be purged every 8 hours thanks
to a grease line from the seal pack to the top of
the pump
-
Clogging prevented and positive input provided
-
Shear plate has two legs to help support pump off
the floor of the pit
-
Impeller transition area features beefed-up steel
for long life
-
Pump available in various lengths to fit pit depths
of 3 12 feet
|
|
Patz
Model 4444 Vertical Pit Pump |
-
Pumping capacity up to 1,580 gals./min
-
Available in lengths to fit your application: 6
ft. (1.8 m), 8 ft. (2.4 m), 10 ft. (3.0 m), and
12 ft. (3.6 m)
-
A 16-inch (40.6 cm) Impeller for added capacity
-
Variable agitation capacities with a standard dual
agitation system
-
Abrasion-resistant steel in high wear areas for
longer life
-
Tapered-bore drive pulley mounts to a 1-3/4 inch
(44.5 mm) drive shaft with a greaseable flange bearing
at the top of the drive tube
-
Easy access to oil reservoir
-
Lifting loops located on top of the pump allows
easy insertion and removal of the unit from the
pit with a tractor loader, skid-steer loader or
winch
-
A steel mounting plate is included as standard equipment
to allow precise positioning of the pump to match
the pit depth. Plate can be lagged to a concrete
pad or curb
-
Pump available in various lengths to fit pit depths
of 5 ft. 6 in. (1.7 m) to 12 ft 10 in. (3.9 m)
|
|
6000
& 8000 PTO Drive Vertical Pit Pumps |
-
Stationary base secured to manure pit or two-point
tractor hitch with hydraulics for tilting
-
Match your pit depth with choice of four pump lengths:
6, 8, 10 and 12 feet (1.83, 2.44, 3.05 and 3.66
m)
-
Large U-bolts allow the frame to be adjusted up
or down for precise placement
-
Match your desired speed of transfer and loading
with two pump sizes: 6-inch (152 mm) and 8-inch
(203 mm) pipe
-
Reduce agitation time with dual nozzles that blend
crusted manure and settled solids into a liquid
slurry fast
-
Get better pit clean out by agitating every corner
with adjustable nozzles (rotate both horizontally
and vertically)
-
Remove clumps of straw with chopping action over
impeller shredder plate
-
Lower repair costs with impeller housing of abrasion-resistant
steel in high-wear areas
-
Tractor Requirement: 100 HP minimum
|
|
Model 6000E Electric Drive Vertical Pit Pump |
-
A stationary base secured to manure pit is standard
on the 6000E Pump
-
Equipped with a two-point tractor hitch for easy
insertion and removal from pit for service
-
Match your pit depth with choice of four pump lengths:
6, 8, 10 and 12 feet (1.83, 2.44, 3.05 and 3.66
m)
-
Large U-bolts allow the frame to be adjusted up
or down for precise placement
-
Get better pit clean-out by agitating with a nozzle
which can be rotated horizontally
-
Save time when agitating, transferring, and loading
due to swept-back impeller blades for high-volume
pumping up to 2,500 gallons per minute-during agitation
and 2200 gallons per minute during loading
-
Horsepower Requirements: Twin 15, 20, 25, or 30
HP, 3-phase motors
|
|
Patz Model 9000 Liquid Transfer System |
-
Pump: 1/2 hp. 1625 RPM: Single phase; 230 volts;
5.8 amps; 84 lb. (38 kg); maximum solids diameter:
2" (50.8 mm); two-vane, non-clogging impellers
-
Pump Performance: G.P.M. at total head in feet
-
Gutter Widths: 15" to 20"
-
Hole Size for Installation: 18" (457 mm) wide
x 24" (610 mm) long x 30" (762 mm) depth
below gutter bottom (20 gal. sump)
-
Pipe Size: 2" (50.8 mm) PVC schedule 40 Pipe
supports should be every 10' (3m) apart
-
Height to top of handle: 19-3/8"
-
Width at widest point: 12-5/8"
-
Discharge: 2 NPT
-
Suction inlet opening: 2"
-
Weight: 84 lb.
|
|
|
|
|